Aer Extension Kit Installation



i Unscrew the Nut anti-clockwise, using the flat side of the Tool. Alternatively you can use any large flat head screwdriver that fits with the Nut cutouts [b]. Most large flat head screwdrivers will do the job. Avoid using smaller sized screwdivers, also avoid using phillips screwdrivers, as this might lead to tear and wear of the Nut due to bad application / fitting.

i Keep the Seal and the Nut aside, and assemble the Extended Tank Section, first with the parts out of the Extension Kit, that is the Extended Chimney, the Extended Tank Body, the Extended LFC Tube and the 9×1.5 O-ring. i Important to note no1: Before you place the Seal and the Nut on top of the Extended Tank Section, you need to make sure that the Extended LFC Tube is set to “liquid shut off” position. Rotate the Extended LFC Tube until the liquid slots on its base are fully aligned with the kidney shaped blind engravings right under [black arrows b].
iImportant to note no2: Now for the Seal assembly. The Seal does not sit randomly on the Chimney top. You need to spot the two female cutouts at the top part of the Chimney [blue arrows b], where the corresponing protruding parts of the Seal bottom should fall in. For this, slowly rotate the Seal on top of the Extended Chimney, until it falls in place.
i When everything is assembled, Seal on top and Extended LFC Tube properly aligned, they should look like image [c]. The two small protruding edges of the Extended LFC Tube should appear as rotated fully anti-clockwise until start point of their carved route [yellow arrows c].
i You can now re-place the Top Cap and the Extended Tank Section on top of the Base of the Aer, following Aer manual step 2.